Plug drawings follow the site convention: contacts facing you, latch at the back, pins on the left, cable to the right, pin 1 at the bottom.
Covers the three-phase hybrids HIT-5L-G3 … HIT-20L-G3 (global and AU versions).
Which port
Connect the dongle to the Meter_2 port in the COM1 block. Meter_1 is taken by the energy meter shipped with the inverter. Do not use the Parallel, BMS or DRM ports.
Meter_2 port
| Pin | Signal (Hoymiles) | Dongle terminal | T568B colour |
|---|---|---|---|
| 1, 2, 3 | NC | – | |
| 4 | 485A | A | blue |
| 5 | 485B | B | white-blue |
| 6 | GND | GND (optional) | green |
| 7, 8 | NC | – |
✅ Confirmed in the Three-phase Hybrid Inverter HIT-(5-20)L-G3 manual (section 7.7 COM1 Connection). Meter_1 has the same pinout.
Trap: the top row of ports is upside down
COM1 is a 2×3 block of RJ45 sockets. According to the manual’s drawing, the top row (Parallel_2, Meter_2, BMS) is mounted upside down: the latch slot is at the top and pin 1 is on the right as you look into the socket. The bottom row (Parallel_1, Meter_1, DRM) has the latch slot at the bottom and pin 1 on the left.
In practice: the plug goes into Meter_2 latch up. The pin numbering inside the plug does not change, so a cable crimped per the table above is correct. Only what you see when counting pins in the socket changes.
The global manual (2025) draws every socket in its pin table the same way: latch down, pins 1…8 from the left, T568B colours. That is the bottom-row view. The newer AU manual (REV0.5, 2026) draws the top-row sockets, Meter_2 included, latch up and numbered 8…1 from the left, which confirms the inversion.
Alternative: 485_2 terminals in COM2
Hoymiles designates the 485_2 terminals of the COM2 terminal strip (0.5–0.8 mm² wire) for third-party control and VPP. We have not tested GbbDongle on them. ⚠️ Not verified.
Support status
Whether the inverter works with GbbDongle depends on support in GbbOptimizer. Ask on the GbbDongle Discord channel before you buy hardware for a Hoymiles.
Sources
- Hoymiles, Three-phase Hybrid Inverter HIT-(5-20)L-G3 User Manual, sections 7.7 and 7.8: PDF (hoymiles.com)
- Hoymiles, Three-phase Hybrid Inverter HIT-(5-20)L-G3-AU User Manual REV0.5, section 7.7 (table names Meter_2 explicitly): PDF (hoymiles.com)