Deye

Modbus and Meter-485 ports on Deye inverters: pins 1 (B) and 2 (A).

Plug drawings follow the site convention: contacts facing you, latch at the back, pins on the left, cable to the right, pin 1 at the bottom.

Three-phase hybrids SG04LP3 and SG05LP3

Covers e.g. SUN-5…12K-SG04LP3-EU and SUN-3…20K-SG05LP3-EU-SM2.

Which port

The RJ45 port labelled Modbus (on the SG04LP3 and SG05LP3, the second from the right). If another device uses Modbus, the dongle also works on the Meter-485 port. Do not use the BMS, CAN or Parallel ports.

Modbus port

Deye Modbus port: pin 1 485 B, pin 2 485 A, pins 3 and 6 GND

PinSignal (Deye)Dongle terminalT568B colour
1SUNSPE-485_BBwhite-orange
2SUNSPE-485_AAorange
3GND_SUNSPE-485GND (optional)white-green
4, 5––
6GND_SUNSPE-485GND (optional)green
7SUNSPE-485_A(second A)white-brown
8SUNSPE-485_B(second B)brown

Pins 7 and 8 are the same bus as pins 1 and 2. They daisy-chain the next inverter in a master/slave setup: always connect A to A (pin 2 or 7) and B to B (pin 1 or 8). The FAQ section “Several inverters (Deye master/slave)” describes such an installation.

Meter-485 port

Deye Meter-485 port: pin 1 485 B, pin 2 485 A, pin 3 GND

PinSignal (Deye)Dongle terminal
1METER-485-BB
2METER-485-AA
3COM-GNDGND (optional)
4, 5, 6METER-485-B, METER-485-A, COM-GND–
7, 8METER-485-A, METER-485-B–

Meter-485 repeats the same signals on pins 4/5 and 7/8, so the 1/2 pair is enough.

Status

✅ Confirmed in the SUN-(14-20)K-SG05LP3-EU-SM2 manual (Appendix I, manual page 49, PDF page 51). The SUN-(8-12)K-SG04LP3 manual (Ver 2.1, 2021-04) gives the same Meter-485 pinout and still lists the Modbus port as “Reserved”: on older units use Meter-485 or update the inverter firmware. Solar Assistant shows the same layout for every Deye model: pin 1 RS485B, pin 2 RS485A.

How Deye draws the connector

The Deye manual shows the socket from the front with the latch slot at the bottom, pins 1…8 from the left. That matches what you see looking into the inverter’s port. Next to it is a perspective drawing of the plug: tip to the left and cable to the right as here, but the latch is on top and the 8…1 numbering runs diagonally. Do not carry that numbering straight over to our convention, where the latch is at the back.

Single-phase hybrids (SG01LP1, SG02LP1, SG03LP1, SG04LP1, SG05LP1)

Solar Assistant gives the same layout for the RS485 port as on the three-phase models: pin 1 B, pin 2 A. On older 5 kW units, Solar Assistant points to the BMS 485 port, not the one labelled “RS 485”.

🟡 We have not checked this in Deye’s single-phase manuals.

A note on A and B naming

Deye calls pin 2 “A” and pin 1 “B”, and Solar Assistant labels them the same way. Some integrations (e.g. the Eniris documentation) wire Deye pin 1 to the “A” terminal of their converter, the other way round. If the dongle gets no answer, swap A and B.

Sources