GbbDongle talks to the inverter over two RS485 wires (A and B), optionally a third (GND). This page shows which inverter port to use and which pins carry those signals. Every RJ45 plug on this site is drawn in one orientation, whatever the manufacturer’s drawing looks like.
How to read the drawings
Hold the plug like this:
- contacts (gold blades) facing you,
- latch at the back, away from you,
- contact end to the left, cable leaving to the right.
In this position pin 1 is at the bottom and pin 8 at the top. Wire colours in the drawings follow T568B, the scheme most ready-made network cables use.
Rules that always apply
- A to A, B to B. The pin the manufacturer calls A (RS485 A, 485_A, RS485+) goes to the dongle’s A terminal, B to B. GND is optional, but worth connecting on long cables and with several inverters.
- Count pins, not colours. A cable may be crimped as T568A, which swaps the orange and green pairs. Check the cable with a tester or a multimeter.
- No answer? Swap A and B. Inverter and adapter makers disagree on which line is “A”. Swapping the wires does no harm.
- One polling device per bus. The dongle cannot share the same wires with SolarAssistant, a Wi-Fi logger or another Modbus integration (see the FAQ).
- Inverter settings: Modbus address 1, 9600 baud, 8N1, unless you changed it in the dongle’s web panel.
- Never connect supply pins (+5 V, +12 V, VCC) to the dongle.
Traps in manufacturer drawings
Manufacturers draw the RJ45 connector in several ways and do not always say from which side. Before you copy a pin number from a manual onto a cable, work out what is drawn.
| What the drawing shows | Where pin 1 is |
|---|---|
| Socket from the front, latch slot at the bottom | on the left |
| Socket from the front, latch slot at the top (socket mounted upside down) | on the right |
| Plug from the contact side, tip up, cable down | on the left |
| Plug end-on (looking into the tip), latch at the bottom | on the right |
Upside-down sockets do exist: on Hoymiles HiT inverters the top row of the COM1 block (including Meter_2) is mounted the other way up from the bottom row. Felicity draws its socket latch-up, numbered 8…1 from the left. Each brand page says how its source is drawn.
Summary
| Inverter | Port | A | B | GND | Source |
|---|---|---|---|---|---|
| Deye three-phase SG04LP3 / SG05LP3 | Modbus (RJ45) | 2 | 1 | 3 or 6 | ✅ Deye manual |
| Deye three-phase SG04LP3 / SG05LP3 | Meter-485 (RJ45) | 2 | 1 | 3 | ✅ Deye manual |
| Deye single-phase SG0xLP1 | RS485 (RJ45) | 2 | 1 | – | 🟡 Solar Assistant |
| Solis S6-EH3P (three-phase 8–20 kW) | RS485 (RJ45) | 1 | 2 | – | ✅ Solis manual |
| Solis S6-EH1P (single-phase) | RS485 (RJ45) | 5 | 4 | – | ✅ Solis manual |
| Hoymiles HiT HIT-(5-20)L-G3 | Meter_2 (RJ45, top row, upside down) | 4 | 5 | 6 | ✅ Hoymiles manual |
| Felicity T-REX-10KLP3G01 / 15KLP3G01 | COM (terminal block) | 4 | 3 | – | 🟡 German 10K manual only |
| Felicity T-REX HP (e.g. 50KHP3G01) | RS485 (RJ45) | 3 | 4 | – | 🟡 manufacturer table via Solar Assistant |
Legend: ✅ confirmed in the manufacturer’s manual, 🟡 indirect or incomplete source, ⚠️ not verified. None of these replaces a look at the port labels on your own unit: manufacturers change boards between revisions.
Your model is missing or something does not match? Ask on the GbbDongle Discord channel, ideally with a photo of the port and the manual page.